SolarPower

From JoBaPedia
Jump to navigation Jump to search

OpenDTU

Balkonkraftwerk

My "Balkonkraftwerk" uses OpenDTU to query the rf data of the microinverter TSOL-M800 from TSUN (Hoymiles HM600 compatible).

Monitoring Setup

Troubleshooting

Garagenkraftwerk

My "Garagenkraftwerk" uses Tasmota to query power data and control a fan via Nous power plugs

LiFePO-Island

My shed in the garden has LiFePO backeded solar power

  • Power route: Panel -> Esmart3 -> BMS -> 12V LiFePOs -> Inverter -> 220 V / 500 W continuous power (7 switchable output plugs)
  • Control/Monitoring: The BMS and the ESmart3 report to an ESP32 via RS485 serial line.
  • The ESP32 is behind a Tasmota port forwarding range extender http://nat2, reachable via http://nat2:8080
  • The ESP32 runs my firmware https://github.com/joba-1/LiFePO_Island which posts data to influx
  • Influx DB (influx --database LiFePO_Island --execute "show measurements" for all available data tables
    • ESmart3 charge and load status: influx -precision rfc3339 --database LiFePO_Island --execute 'select * from ChgSts order by time desc limit 10'
    • BMS cell voltages: influx -precision rfc3339 --database LiFePO_Island --execute 'select * from Cells order by time desc limit 10'